“ALTAIR” – LED lamps is developed on the latest trends in lighting technology (super bright LED, CREE USA, Pb-Free) and to meet the requirements of the European Community. The high quality and relatively low cost of products is result of using the latest technology and an own develop.
Purpose: lighting of highways, streets, roads, squares, yards, parking lots, bridges, tunnels, passages, gas stations, railway platforms, and any open spaces.
Basic features:
Description
|
Model
|
RL-01/20
|
RL-01/28
|
RL-01/40
|
Climatic marking and allocation category
|
IP 54 temperature range - 40°C
+ 40°C
|
Safety range
|
SSS IEC 60598-1
|
Supply voltage, V
|
220 ± 10%
|
Line frequency, Hz
|
50
|
Power consumption, W, no more
|
68
|
95
|
136
|
Class of distribution light
|
direct light under SSS17677
|
Type of luminous intensity distribution curve (LIDC)
in longitudinal plane
|
deep under SSS17677
|
Type of luminous intensity distribution curve (LIDC)
in cross plane
|
cosine under SSS17677
|
Luminous flux, lm, no less
|
3750
|
5250
|
7500
|
Correlated color temperature, K
|
7000 (cold white)
|
Lamp life time in city illumination mode
|
1000
|
LED manufactured
|
CREE (USA)
|
Overall dimensions, mm
|
543x150x92
|
543x150x92
|
648x150x92
|
Weight, kg, no more
|
6.2
|
6.5
|
7.9
|
Case color
|
Base - silver, customize - any
|
*SSS – State Standard Specification
Design features of lamps:
- Lamp case is a heater as well that increase efficiency and reduce the device weight
- Increased case ruggedness and attachment point against bearing structure provide an ease installation and maintenance
- Small size of lighting compartments makes a possibility to reduce condensate rate there at daily range of air temperature
- Availability of captive relief fitting provides convenient condensate drain from the lamp case during maintenance
- Lamp can be equipped with lighting protection unit additionally
- Small weight of lamp enabled to hang it up on tension cables e.g. in the middle of the street (available to order)
- Design hardware parts made of stainless steel
- Construction separation of lamp case and electronics package provides a convenient access to electrical circuit units during maintenance
- Careful design of materials, galvanic and lacquer coatings guarantees maintainability and noncorrodibility of the lamp during its life time
- Usage of polycarbone sheet glass provides vandal resistance
- Due to lamp design features it is recommend to apply it in regions with high wind activity
Application: street illumination management
Advantages of LED lamps over Hg-lamps
- Electricity consumption is 3.5 times less
- Minimal maintain
- Withstand ability against voltage drops
- Absence of stroboscope effect
- High contrast range and color reproduction
- Environmental safety
- Warranty times 4 years
Comparison characteristics of standard sodium lamp 400 W
and LED lamp RL-01/40
№
|
Description
|
Sodium lamp 400W
|
LED lamp REC
Altair RL-01/40
|
1.
|
Power consumption, W
|
400
|
136
|
2.
|
Choke consumption, W
|
50
|
---
|
3.
|
Starting current, А
|
2,9
|
0,33
|
4.
|
Working current, А
|
1,8
|
0,33
|
5.
|
Correlative color temperature, K
|
1950
|
7000
|
6.
|
Color Rendering Index, Ra
|
25
|
80
|
7.
|
Min supply voltage when lamp keeps its operability,
V
|
160
|
60
|
8.
|
Availability of toxic substances
|
A
|
N/A
|
9.
|
Recovery requirement
|
A
|
N/A
|
10.
|
Stroboscopic effect
|
A
|
N/A
|
11.
|
Sound pressure
|
A
|
N/A
|
12.
|
Emitted and electromagnetic interference
|
A
|
N/A
|
13.
|
Color rendering index , Rа
|
25
|
80
|
14.
|
Starting mode time
|
up to 3
min
|
up
to 1 sec.
|
15.
|
Life time
|
up to 10 000 hours
|
up to 100 000 hours
|
16.
|
Operating temperature rate, °С
|
-40 ...+45
|
-40 ...+45
|
17.
|
Supply voltage rate when luminous
flux shift is up to 5% of
basic, V
|
185-235
|
100-260
|
18.
|
Vibration stability
|
N/A
|
A
|
19.
|
Vandal resistance
|
N/A
|
A
|
20.
|
Operability at semiperiodic supply voltage
|
N/A
|
A
|
21.
|
Anti-jamming
|
N/A
|
A
|
22.
|
Maintenance (inductor,
lamp replacement)
|
required
|
unrequited
|
*A - available, N/A - not available.
|
- The usage of LED lamps reduces cable load and transforming station more than 5 times due to reduced consumed power;
- For the assembling of LED lamps the cable with less section is required (it means more inexpensive) and efforts are reduced as well accordingly, as a result – additional capital saving;
- During the usage of sodium lamp reflector reflection power reduces (very often we can see lamps without reflectors at all on streets) due to reducing of luminous flux up to 20…40 %;
- In comparison with sodium lamp white light of LED lamp enh
|